On Approval of the Technical Regulation on Measuring Instruments
Text of the document
📑 Contents (30 articles)
On Approval of the Technical Regulation on Measuring Instruments
Government of Georgia
Resolution No. 480
31 December 2024
Tbilisi
On Approval of the Technical Regulation on Measuring Instruments
Article 1🔗
Pursuant to paragraph 1 of Article 56 and paragraph 2 of Article 58 of the Code of Product Safety and Free Movement, the attached "Technical Regulation − on Measuring Instruments" (hereinafter – the Technical Regulation) shall be approved.
Article 2🔗
LEPL – National Agency of Standards and Metrology of Georgia publishes standard(s) (name(s) of standards) that ensures the fulfillment of the requirements of the Technical Regulation approved by this Resolution.
Article 3🔗
The LEPL – Market Surveillance Agency (hereinafter – the Agency) shall be designated as the body exercising market surveillance over the products provided for by the Technical Regulation approved by this Resolution.
Article 4🔗
1. The Agency is entitled to verify the conformity of measuring instruments placed on the market of Georgia with the requirements of the Technical Regulation approved by this Resolution and, if necessary, in accordance with the legislation of Georgia, to issue appropriate recommendations to bring the measuring instruments into conformity.
2. The relevant economic operator shall cooperate with the Agency for the implementation of the measures provided for by paragraph 1 of this Article and shall ensure the admission of the representative of the market surveillance body to the places of sale of the product, as well as, upon request, provide it with the information and documents necessary to determine the conformity of the product.
Article 5🔗
1. LEPL – Revenue Service (hereinafter – Revenue Service) is authorized, where there is reasonable suspicion and/or based on a risk management system, to suspend the product and notify the Agency thereof, for the purpose of implementing market surveillance measures provided for by the legislation of Georgia. For the same purpose, the Agency is authorized, where there is reasonable suspicion and/or based on risk analysis, to apply to the Revenue Service regarding suspension of the product. In such cases, the Revenue Service shall suspend the product for the period provided for by this article for inspection of the product and shall not allow placement of such product on the market of Georgia through import.
2. The Agency is authorized, in the case provided for by paragraph 1 of this article, in agreement with the Revenue Service, to carry out market surveillance provided for by the legislation of Georgia in the customs control zone of Georgia, no later than 3 working days from receipt of information from the Revenue Service, except in cases where laboratory examination is necessary to determine conformity of the product.
3. To exercise the authority provided for by this article, the Agency is authorized to take a sample of the product in the customs control zone of Georgia, for the purpose of testing it in an appropriately accredited laboratory.
4. If laboratory examination of a sample is necessary to determine conformity of the product, the Agency shall determine conformity of the product with the technical regulation within 2 working days from submission to the Agency of the relevant expert opinion on laboratory examination of the product sample.
5. If within the period provided for by this article it is established that the product does not comply with the requirements of the Code on Product Safety and Free Movement and/or the technical regulation approved by this Resolution and/or contains a confirmed hazard, the Revenue Service shall not allow placement of such product on the market of Georgia through import.
6. If within the period established by the customs legislation of Georgia it is not possible to determine release for free circulation (import) or another customs procedure/re-export, in respect of the goods, by decision of the customs authority, the goods disposal measures provided for by Chapter XV of the Customs Code of Georgia shall be carried out at the expense of the owner/importer of the goods.
Article 6🔗
Compliance with the requirements of the countries provided for by Article 3 of Resolution No. 50 of 7 March 2013 of the Government of Georgia "On the admission of technical regulations of other countries to operation in Georgia, recognition of conformity documents, admission of products bearing the relevant marking to Georgia without additional conformity assessment procedures, and also on the placing on the market of Georgia without restrictions of products manufactured in other countries and falling within the regulated sphere" shall be deemed to also satisfy the requirements of the technical regulation approved by this Resolution, which is confirmed by the procedure established in the same countries for conformity assessment, including by conformity documents. The said documents shall be submitted in the Georgian language.
Article 7🔗
1. The Resolution, except for Articles 3 and 4 of the Resolution and this Article, shall enter into force from 1 December 2028.
2. Articles 3 and 4 of the Resolution and this Article shall enter into force upon publication.
3. Article 4 of the Resolution shall be in force until 30 November 2028 inclusive. Prime Minister Irakli Kobakhidze Technical Regulation − on measuring instruments
Article 1. Scope🔗
1. This technical regulation determines the requirements for the design and production of measuring instruments made available on the market for the purposes of ensuring public interest, consumer health and safety, order and environmental protection, the imposition of taxes and fees, and fair trade.
2. This technical regulation applies to the following measuring instruments:
a) water meters;
b) gas meters;
c) electricity meters;
d) thermal energy meters;
e) flow measuring instruments (systems) used for liquids other than water;
f) automatic weighing instruments (automatic scales);
g) liquid level measuring instruments in vessels (tank, reservoir and others) (material measures);
h) vehicle exhaust gas analysers.
Article 2. Definitions of Terms🔗
1. For the purposes of this Technical Regulation, the terms used have the following meanings:
a) measuring instrument – any device or system with a measuring function as defined by paragraph 2 of Article 1 of this Technical Regulation;
b) component – any material device referred to as such in the specific annexes for measuring instruments, which operates independently and forms a measuring instrument together with other components with which it is compatible or together with a measuring instrument with which it is compatible;
c) notified body – a body authorised by legislation or accredited in the appropriate form, which has been empowered by an EU Member State (or another country with which the EU has a specific agreement) to carry out conformity assessment of a product with EU harmonised legislation before its placing on the market. The list of notified bodies is published by the European Commission;
d) normative document – a document containing technical specifications adopted by the International Organization of Legal Metrology;
e) making available on the market – any supply of a measuring instrument for distribution or use in the course of a commercial activity, for consideration or free of charge;
f) placing on the market – the first making available on the market of a measuring instrument in the territory of Georgia, except for free industrial zones;
g) recall – an action aimed at the return of a measuring instrument that has already been supplied by the manufacturer or distributor or is otherwise available to the user;
h) withdrawal from the market – an action aimed at terminating the distribution, offering to the user or supply of a measuring instrument;
i) manufacturer – any natural or legal person who designs and manufactures a measuring instrument and markets it under its own name or trade mark;
j) authorised representative – any natural or legal person who has been authorised in writing by the manufacturer to perform the relevant functions in its name and/or under its trade mark;
k) importer – any natural or legal person who places on the market of Georgia a measuring instrument originating in another country;
l) distributor – any natural or legal person in the supply chain (other than the manufacturer and the importer) who makes a measuring instrument available on the market;
m) economic operator – the manufacturer, authorised representative, importer and distributor;
n) technical specification – a document containing the technical requirements that a measuring instrument must satisfy.
2. Other terms used in this Technical Regulation, except for the terms provided for by paragraph 1 of this Article, shall be governed by the definitions of terms of the Code of Product Safety and Free Movement.
Article 3. Extension to constituent parts🔗
1. If the specific annexes of this technical regulation corresponding to measuring instruments establish essential requirements for constituent parts, this regulation shall extend to such constituent parts subject to the necessary amendments.
2. For the purposes of establishing conformity, constituent parts and measuring instruments may be assessed independently and separately.
Article 4. Essential requirements🔗
1. The measuring instruments defined by paragraph 2 of Article 1 of this technical regulation shall comply with the essential requirements established by Annex I to this technical regulation.
2. The information indicated in paragraph 9 of Annex I to this technical regulation or in the specific annexes corresponding to the measuring instrument shall be presented in the Georgian language.
Article 5. Ensuring availability on the market🔗
1. The measuring instruments defined by paragraph 2 of Article 1 of this technical regulation, when placed on the market, shall comply with the requirements of this technical regulation.
2. Measuring instruments which fail to comply with the requirements established by this regulation shall not be admitted to the market.
3. The measuring instrument shall comply with such provisions regulating putting into operation as are conditioned by local climatic conditions. In such case, the corresponding upper and lower temperature limits shall be selected from the first table of Annex I and humidity conditions (condensing or non-condensing) may be established, as well as the intended location of use – indoor or outdoor space.
4. If different accuracy classes are defined for the measuring instrument:
a) in the specific annexes for measuring instruments, under the heading "putting into operation", accuracy classes may be indicated which shall be used for specific purposes;
b) in all other cases, within the defined classes, accuracy classes for specific purposes may be established, provided that the use of all accuracy classes on the territory of Georgia is permitted.
5. For the purposes of subparagraphs "a" or "b" of paragraph 4 of this Article, a measuring instrument of a better accuracy class may be used, if the owner so decides.
6. At fairs, exhibitions or similar events, measuring instruments which are not in conformity with this technical regulation may be presented, provided that a visual sign clearly shows their non-conformity and the impossibility of placing them on the market and/or putting them into operation, until they are brought into conformity.
Article 6. Manufacturer's obligations🔗
1. When placing on the market measuring instruments defined by paragraph 2 of Article 1 of this Technical Regulation, the manufacturer shall ensure that they are designed and manufactured in accordance with the essential requirements laid down by Annex I to this Regulation and the specific annexes relevant to measuring instruments.
2. The manufacturer shall draw up the technical documentation provided for by Article 14 of this Technical Regulation and carry out the conformity assessment procedure provided for by Article 13 of this Regulation or ensure that the procedure has been carried out. If the conformity assessment procedure confirms that the measuring instruments comply with the relevant requirements of this Technical Regulation, the manufacturer shall draw up a declaration of conformity, affix the marking and the additional metrological marking, where required.
3. The manufacturer shall keep the technical documentation and the declaration of conformity for measuring instruments provided for by paragraph 2 of Article 1 of this Technical Regulation for 10 years from the placing of the measuring instruments on the market.
4. The manufacturer shall, during serial production, implement all necessary procedures so that the measuring instrument complies with the requirements provided for by this Technical Regulation. The manufacturer shall take into account changes in the design or characteristics of the measuring instruments, as well as changes in the standards or other technical specifications on the basis of which the declaration of conformity was drawn up.
5. Where necessary, in relation to the risks of measuring instruments provided for by paragraph 2 of Article 1 of this Technical Regulation, the manufacturer shall carry out testing and examination of samples of measuring instruments available on the market and withdrawal of non-compliant measuring instruments; in such a case, the manufacturer shall keep a register of complaints and withdrawn measuring instruments. Distributors shall be informed of such non-compliance.
6. The manufacturer shall, for identification purposes, ensure that the relevant type, batch or serial numbers or other elements are affixed to the measuring instruments, allowing their identification. If this is not possible due to the size or specific nature of the measuring instruments, the manufacturer shall ensure that the necessary information is provided in the accompanying documentation and on its packaging, if any, in accordance with paragraph 9.2 of Annex I to this Regulation.
7. The manufacturer shall affix to the measuring instrument its own name, registered trade name or registered trade mark and an address at which it can be contacted, and where this is not possible, the information shall be affixed in the accompanying documentation of the measuring instrument and on its packaging, if any, in accordance with paragraph 9.2 of Annex I to this Regulation. The address shall contain a single contact address at which the manufacturer can be contacted. The contact information shall be provided in the Georgian language.
8. The manufacturer shall attach to the measuring instrument it has placed on the market a copy of the declaration of conformity and the instructions and safety information, in accordance with paragraph 9.3 of Annex I to this Regulation, in the Georgian language. Such instructions and safety information, as well as any label, shall be clear, legible and understandable.
9. A manufacturer which considers, or has reasonable grounds for suspicion, that a measuring instrument it has placed on the market does not comply with the requirements of this Regulation, shall immediately take the necessary corrective measures to bring the said measuring instrument into conformity, and, where necessary, suspend its sale, withdraw the product from the market or recall it from the market. In addition, where the measuring instrument presents a risk, the manufacturer shall immediately notify the Agency thereof and provide detailed information, in particular about the non-compliance and the corrective measures taken.
10. The manufacturer shall, on the basis of a reasoned request from the Agency, provide in material or electronic form all information and documents, completed in the language defined by the Code of Product Safety and Free Movement, which are necessary to confirm the conformity of the product with this technical regulation. The manufacturer shall cooperate with the Agency in relation to all measures taken to avert the risks arising from measuring instruments placed on the market by it.
Article 7. Authorised representative🔗
1. A manufacturer may, on the basis of a written mandate, appoint an authorised representative, except for the obligations defined by paragraphs 1 and 2 of Article 6 of this Regulation.
2. The authorised representative shall perform the functions provided for by the powers conferred on it by the manufacturer. The powers shall enable the authorised representative to perform at least the following functions:
a) keep the declaration of conformity and technical documentation for 10 years from the placing of the measuring instrument on the market, for submission to the market surveillance authority;
b) upon the Agency's request, submit all necessary documentation and information confirming the conformity of the measuring instrument;
c) upon a relevant request, cooperate with the Agency in connection with measures taken for the purpose of eliminating risks posed by measuring instruments, within the scope of the authorised representative's mandate.
Article 8. Obligations of the importer🔗
1. The importer shall place on the market only measuring instruments that comply with the requirements of this Technical Regulation.
2. Before placing on the market and/or putting into service a measuring instrument defined by Article 1(2) of this Regulation, the importer shall make sure that the appropriate conformity assessment procedure provided for by Article 13 of this Regulation has been carried out by the manufacturer. The importer shall also make sure that the manufacturer has drawn up the relevant technical documentation, that the measuring instrument bears the marking and additional metrological marking and is accompanied by a copy of the declaration of conformity and the required documentation, and that the manufacturer has satisfied the requirements laid down by paragraphs 6 and 7 of Article 6 of this Technical Regulation.
3. If the importer considers or has reasonable doubt that the measuring instrument does not comply with the essential requirements laid down in Annex I to this Regulation or in the specific annexes relevant to the measuring instrument, it shall not place the measuring instrument on the market until the measuring instrument has been brought into compliance. If the measuring instrument presents a risk, the importer shall inform the manufacturer and the market surveillance authority thereof.
4. The importer shall affix to the measuring instrument its own name, registered trade name or registered trade mark and the address at which it can be contacted, or, where this is not possible, the information shall be provided in the accompanying documentation of the measuring instrument and on its packaging, if any, in accordance with paragraph 9.2 of Annex I to this Regulation. Contact information shall be provided in Georgian or English.
5. The importer shall ensure that the measuring instrument is accompanied by instructions and safety information in Georgian in accordance with paragraph 9.3 of Annex I to this Regulation.
6. The importer shall ensure that, during the period when the measuring instrument is under its responsibility, the conditions of storage and transport do not endanger its compliance with the essential requirements provided for in Annex I to this Regulation and in the specific annexes relevant to measuring instruments.
7. Where necessary, the importer shall, in relation to the functioning of measuring instruments, carry out testing of samples of measuring instruments available on the market, where necessary keep a register of complaints, as well as of non-compliant and withdrawn measuring instruments, and inform distributors about such monitoring.
8. An importer who considers, or has reasonable grounds to suspect, that a measuring instrument placed on the market by it does not comply with the requirements established by this Regulation shall immediately take the necessary corrective measures to bring the said measuring instrument into conformity and, where necessary, withdraw or recall the measuring instrument from the market. If the measuring instrument presents a risk, the importer shall immediately notify the market surveillance authority thereof and provide it with the relevant information on the non-compliance and the corrective measures taken.
9. The importer shall, for 10 years from the placing of the measuring instruments on the market, keep a copy of the declaration of conformity for submission to the market surveillance authority and shall ensure that, upon request, the technical documentation is provided to that authority.
10. The importer shall, on the basis of a reasoned request of the market surveillance agency, submit in material or electronic form, in the Georgian language, all information and documents necessary to confirm the conformity of the measuring instrument with this technical regulation. The importer shall, upon request, cooperate with the market surveillance authority in respect of the measures taken by them to avert the risks arising from the measuring instruments placed on the market.
Article 9. Obligations of the distributor🔗
1. When making a measuring instrument available on the market and/or putting it into service, the distributor shall duly comply with the requirements of this Regulation.
2. Before placing on the market a measuring instrument defined by paragraph 2 of Article 1 of this technical Regulation, the distributor shall ensure that the measuring instrument bears the marking and the supplementary metrological marking, is accompanied by the declaration of conformity, in the form of the information and instructions required in accordance with paragraph 9.3 of Annex I to this Regulation, in the Georgian language, and that the manufacturer and the importer have fulfilled the requirements laid down by Article 6(6) and (7) and Article 8(4) of this Regulation.
3. If the distributor considers or has reasonable grounds to suspect that a measuring instrument defined by paragraph 2 of Article 1 of this technical Regulation does not comply with the essential requirements laid down in Annex I to this Regulation and the specific annexes applicable to the measuring instrument, it shall not place the measuring instrument on the market until it has been brought into conformity. At the same time, if the measuring instrument presents a risk, the distributor shall inform the manufacturer or the importer and the market surveillance authority thereof.
4. The distributor shall ensure that, during the period under its responsibility, the conditions for storage and transport of measuring instruments do not endanger compliance of the measuring instruments with the essential requirements laid down in Annex I to this Regulation and the specific annexes applicable to the measuring instrument.
5. A distributor which considers or has reasonable grounds to suspect that a measuring instrument placed on the market or put into service by it does not comply with this technical Regulation shall immediately take all necessary corrective measures to bring the measuring instruments into conformity and, where necessary, recall or withdraw it from the market. If the measuring instrument involves a risk, the distributor shall immediately inform the market surveillance authority and provide appropriate information on the non-compliance and any corrective measures taken.
6. The distributor shall, on the basis of a reasoned request from the market surveillance authority, provide in material or electronic form, in the Georgian language, all information and documents necessary to demonstrate the conformity of the measuring instrument. The distributor shall, upon request, cooperate with the market surveillance authority in relation to the measures taken to avoid risks posed by measuring instruments placed on the market by it.
Article 10. Cases of extension of the manufacturer's obligations to importers and distributors🔗
For the purposes of this technical regulation, an importer or distributor shall be considered a manufacturer and the manufacturer's obligations defined by Article 6 shall be extended to it, when it places a measuring instrument on the market under its own name or trade mark or carries out such modification of a measuring instrument already placed on the market as may affect the requirements provided for it by this Regulation.
Article 11. Identification of economic operators🔗
1. For the measuring instruments defined by paragraph 2 of Article 1 of this technical regulation, economic operators shall, upon request, provide the market surveillance authority with the following information:
a) about any economic operator that supplied it with measuring instruments;
b) about any economic operator to which it supplied measuring instruments.
2. An economic operator shall be obliged to ensure the submission of the information indicated in paragraph 1 of this Article for 10 years after the measuring instruments were supplied to it or were supplied by it.
Article 12. Presumption of conformity of measuring instruments🔗
1. A measuring instrument which is in conformity with the standards published by LEPL − National Agency of Standards and Metrology of Georgia for the purposes of implementation of this technical regulation or with the requirements laid down by parts thereof shall be considered also to conform to the essential requirements set out in Annex I to this technical regulation and in the specific annexes relevant to the measuring instrument, which are covered by those standards or parts thereof.
2. Measuring instruments which are in conformity with the parts of the normative documents whose list has been published shall be considered to conform to the essential requirements set out in Annex I to this Regulation and in the specific annexes relevant to the measuring instrument, which are covered by those parts of the normative documents.
3. The manufacturer may use any technical solution which conforms to the essential requirements laid down by Annex I to this technical regulation and by the specific annexes relevant to the measuring instrument. In addition, in order to benefit from the presumption of conformity, the manufacturer must correctly apply the solutions referred to in the standards or normative documents indicated in paragraphs 1 and 2 of this Article.
4. Conformity with the appropriate tests referred to in subparagraph „i“ of paragraph 3 of Article 14 shall be presumed if the relevant testing programme has been carried out in accordance with the documents referred to in paragraphs 1, 2 and 3 of this Article and if the test results ensure conformity with the essential requirements.
Article 13. Conformity assessment procedures🔗
1. Conformity with the requirements defined by Annex II to this Technical Regulation may be achieved by using one of the conformity assessment procedures selected by the manufacturer.
2. Records and correspondence on conformity assessment procedures shall be drawn up in the language defined by the Code on Product Safety and Free Movement.
Article 14. Technical Documentation🔗
1. The technical documentation of a measuring instrument shall clearly reflect its design, production and operation, and shall make it possible to assess the conformity of the measuring instrument with the requirements of this Technical Regulation.
2. The technical documentation shall be sufficiently detailed to ensure conformity with the following requirements:
a) determination of the metrological characteristics;
b) reproduction of the metrological functioning of the manufactured measuring instrument, where the measuring instrument has been duly adjusted using the appropriate designated means;
c) the integrity of the measuring instrument.
3. The technical documentation shall contain the following information, to the extent necessary for the assessment and for the identification of the type and/or the measuring instrument:
a) a general description of the measuring instrument;
b) conceptual designs and production drawings and plans of components, constituent parts, circuits and a.y.;
c) production procedures to ensure consistent production;
d) where necessary, a description of the electronic devices, with drawings, diagrams, a logic block diagram and general information on the software, describing their characteristics and functioning;
e) descriptions and explanations necessary for a better understanding of subparagraphs „b“, „c“, „d“ of paragraph 3 of this Article, including the functioning of the measuring instrument;
f) a list of the standards and/or normative documents applied, in full or in part, in accordance with Article 12 of this Regulation;
g) descriptions of the solutions adopted for the purpose of fulfilling the essential requirements, where the standards and/or normative documents referred to in Article 12 of this Regulation have not been applied, including a list of the other appropriate technical specifications applied;
h) the results of design calculations, examinations, etc.;
i) where necessary, the results of the appropriate examination, to demonstrate that the type and/or the measuring instrument conform:
to the requirements of this Regulation under the declared rated operating conditions and under the established environmental interference conditions;
the durability specifications for gas, water and thermal energy meters, as well as for liquids other than water;
j) type (pattern) examination certificates or design examination certificates, in relation to those measuring instruments that consist of parts identical to the parts specified in the design.
4. The manufacturer shall specify where the stamps and markings have been affixed.
5. Where necessary, the manufacturer shall indicate the conditions of compatibility of the interfaces and constituent parts.
Article 15. Declaration of Conformity🔗
1. The declaration of conformity shall contain a statement that the essential requirements laid down by Annex I to this Technical Regulation and the relevant specific annexes for measuring instruments have been met.
2. The declaration of conformity shall have the form provided for by Annex XI to this Regulation, shall contain the elements laid down by the relevant modules defined by Annex II to this Technical Regulation, and shall be subject to constant updating. The declaration of conformity shall be drawn up in the language defined by the Code on Product Safety and Free Movement.
3. If several normative acts apply to a measuring instrument, in this case a declaration of conformity shall be drawn up taking into account all these acts. The declaration shall contain the identification of the relevant acts, including references to their publication.
4. By drawing up the declaration of conformity, the manufacturer assumes responsibility for the conformity of the measuring instrument with the requirements laid down by this Technical Regulation.
Article 16. Marking🔗
The conformity of measuring instruments defined by paragraph 2 of Article 1 of this Technical Regulation with this Technical Regulation is established by affixing the metrological marking to the measuring instruments defined by paragraph 2 of Article 1 of this Technical Regulation, in accordance with Article 17 of this Technical Regulation. Together with the metrological marking, the marking established by the legislation of Georgia, if any, or the CE marking shall be affixed to the measuring instrument.
Article 17. Additional metrological marking🔗
The additional metrological marking shall consist of the capital letter "M" and the last 2 digits of the year of its affixing, which shall be enclosed in a rectangle.
Article 18. Rules and conditions for affixing marking and additional metrological marking🔗
1. The marking and additional metrological marking provided for by this article shall be affixed to the measuring instrument or its label (plate) in an easily perceivable form, clearly and indelibly. If this is impossible, the marking shall be affixed to the packaging or to the accompanying documentation of the measuring instrument.
2. When a measuring instrument consists of a set of devices that do not constitute component parts, operate together, then the marking and additional metrological marking shall be affixed to the main device of the measuring instrument.
3. Marking and additional metrological marking shall be affixed before placing the measuring instrument on the market.
4. The affixing of marking and additional metrological marking to a measuring instrument may take place during its manufacturing process, if this is justified.
5. Additional metrological marking shall continuously follow the marking.
6. The marking and additional metrological marking shall be continuously followed by the identification number(s) of the notified body/bodies involved in the production control stage, in accordance with Annex II to this technical regulation. The identification number shall be affixed directly by this body or under its instructions, by the manufacturer or authorized representative. The identification number(s) may be followed by another mark indicating a special risk or use.
Article 19. Accredited in-house structure of the enterprise🔗
1. A legal person is entitled to carry out conformity assessment on the matter provided for by Module A2 and Module C2 of Annex II to this regulation through an accredited structural unit.
2. The conformity assessment provided for by paragraph 1 of this article shall be carried out by the legal person through an independent and impartial structural unit (hereinafter – structural unit), which shall be accredited.
3. The accredited in-house structural unit of the enterprise shall comply with the following requirements:
a) it shall have accreditation in the relevant field, in accordance with the legislation of Georgia;
b) the accredited body and its personnel shall be clearly identifiable within the composition of the legal person and shall possess a reporting method that confirms its independence and impartiality before the single national accreditation body;
c) it does not participate in the design, production, supply, installation, operation and maintenance process of the measuring instrument being assessed. At the same time, it is not involved in activities that pose a threat to the independent and impartial performance of its activities;
d) it carries out conformity assessment only for the legal person whose structural unit it represents.
Article 20. Obligations of the conformity assessment body and/or notified body🔗
1. The conformity assessment body and/or notified body shall carry out conformity assessment in accordance with this Technical Regulation and the conformity assessment procedures defined by Annex II to this Technical Regulation.
2. Conformity assessment shall be carried out proportionately, without imposing unnecessary burden on economic operators. The conformity assessment body and/or notified body, in carrying out its activities, shall take into account the size of the enterprise, the sector in which it operates and its structure, the level of technological complexity of the instrument under consideration and the mass or serial nature of the production process. In carrying out the foregoing, the body shall observe the degree of safety and accuracy required for the conformity of the product with the requirements of the Technical Regulation.
3. If the conformity assessment body or notified body finds that the essential requirements defined by Annex I to this Technical Regulation or by the standards published by LEPL – Georgian National Agency for Standards and Metrology for the fulfilment of the purposes of this Technical Regulation are not met by the manufacturer, it shall require the manufacturer to take appropriate corrective measures and shall not issue a certificate.
4. If the conformity assessment body or notified body, after issuing a certificate, finds in the course of conformity monitoring that the measuring instrument no longer complies with the established requirements, it shall require the manufacturer to take appropriate corrective measures and, where necessary, suspend or revoke the certificate.
5. If the manufacturer has not taken appropriate corrective measures or the measures taken do not have the required effect, the conformity assessment person shall accordingly restrict, suspend or revoke the certificate.
Article 21. Market supervision procedures🔗
1. In the process of market supervision of the products defined by this Technical Regulation, the Agency shall be guided by the product market supervision procedures on the Georgian market defined by this Technical Regulation and the Code of Product Safety and Free Movement.
2. If the Agency has reasonable suspicion that a measuring instrument covered by this Technical Regulation poses a risk to human health or safety, it shall carry out the market supervision measures provided for by the Code of Product Safety and Free Movement and shall notify the appropriate conformity assessment body/person thereof, if any. The relevant economic operator shall cooperate with the Agency.
3. The economic operator shall take all necessary corrective measures in respect of all relevant measuring instruments that it has made available on the market.
Article 22. Compliant measuring instruments that present a risk🔗
1. If, as a result of the market surveillance measures carried out in accordance with paragraph 1 of Article 21 of this Technical Regulation, it is revealed that a measuring instrument is compliant with this Regulation and nevertheless presents a risk to human health and safety, it shall be obliged to require the relevant economic operator to take all appropriate measures so that the measuring instrument, when placed on the market, no longer presents a risk, or is withdrawn from the market, or its recall is effected within a reasonable period, proportionate to the risk.
2. The economic operator shall be obliged to ensure that the corrective measure is implemented in respect of all relevant measuring instruments which it has made available on the market.
Article 23. Documentary non-compliance🔗
1. The market surveillance authority shall be obliged to require the relevant economic operator to bring the existing non-compliances to an end in the event of detection of any of the following infringements:
a) the marking or the additional metrological marking is affixed in violation of Article 18 of this Technical Regulation;
b) the marking or the additional metrological marking is not affixed;
c) the identification number of the conformity assessment body and/or the notified body is affixed in violation of Article 18 of this Technical Regulation or is not affixed at all;
d) the measuring instrument is not accompanied by a declaration of conformity;
e) the declaration of conformity is not drawn up correctly;
f) the technical documentation is not available or is incomplete;
g) the information indicated in paragraph 6 of Article 6 or paragraph 4 of Article 8 is absent, incorrect or incomplete;
h) any other administrative requirement established by Article 6 or Article 8 is not fulfilled.
2. If the non-compliance indicated in paragraph 1 has not been corrected/eliminated, the market surveillance authority shall be obliged to carry out the market surveillance measures provided for by the Code of Product Safety and Free Movement.