On Approval of the Rules for Sampling during a Nuclear or Radiological Emergency
Text of the document
📑 Contents (19 articles)
On Approval of the Rules for Sampling during a Nuclear or Radiological Emergency
Government of Georgia
Resolution No. 106
8 April 2025
Tbilisi
On Approval of the Rules for Sampling during a Nuclear or Radiological Emergency
Article 1🔗
Pursuant to subparagraph “b” of paragraph 1 of Article 69 of the Law of Georgia “On Radiation Protection, Nuclear Safety and Security”, the attached “Rules for Sampling during a Nuclear or Radiological Emergency” shall be approved.
Article 2🔗
The Resolution shall enter into force on 1 January 2026.
Prime Minister Irakli Kobakhidze
Rules for Sampling during a Nuclear or Radiological Emergency
Article 1. Objectives and Tasks🔗
1. The “Rules for Sampling during a Nuclear or Radiological Emergency” (hereinafter – the Rules) have been developed in accordance with the Law of Georgia “On Radiation Protection, Nuclear Safety and Security”, as well as the legislation and international requirements in force in the field of radiation protection and nuclear safety.
2. The objective of these Rules is, based on the results of sample testing, to plan response measures to a nuclear or radiological emergency in such a way as to ensure the protection of human beings and the environment from the harmful effects of ionizing radiation.
3. The task of these Rules is to establish the main methods and requirements for sampling during a nuclear or radiological emergency.
Article 2. Scope of regulation🔗
1. The requirements established by this Rule apply to the following cases of nuclear or radiological emergency situation:
a) an emergency situation arising during the use of nuclear and other radioactive materials;
b) an emergency situation during the transportation of nuclear and other radioactive materials and mobile radioactive sources;
c) radioactive sources left without supervision, lost and/or stolen;
d) radioactive contamination of the population and the environment;
e) identification of symptoms of radiation exposure;
f) terrorist threat;
g) illegal circulation of nuclear and other radioactive materials and/or violation of the rules for handling them;
h) damaged radioactive source;
i) radioactive source in a fire area;
j) discovery of an uncontrolled (ownerless) radioactive source;
k) contamination of water, food or consumer products with radionuclides;
l) increase in natural radiation background;
m) transboundary accident as a result of a nuclear or radiological emergency situation occurring at a nuclear and radioactive installation or facility located outside the country's borders;
n) re-entry into the atmosphere of an artificial Earth satellite equipped with a nuclear installation on the territory and/or in the territorial waters of the country.
2. The Rule determines:
a) sampling methods for responding to nuclear or radiological emergency situations;
b) requirements for radiation protection of personnel involved in the sampling process.
3. The requirements established by the Rule shall be binding for implementation by organizations capable of sampling during a nuclear or radiological emergency situation.
Article 3. Definitions of Terms🔗
1. The terms used in this Rule have the following meanings:
a) gamma spectrometry - a research method used to identify radionuclides and determine radiological characteristics;
b) external exposure - exposure to ionizing radiation from open or sealed radioactive sources located outside the human body;
c) decontamination - complete or partial removal of contamination by physical, chemical or biological methods;
d) personal dosimeter - an indirect-reading or direct-reading device intended for measuring individual equivalent dose;
e) contamination - the presence of a radioactive substance on any surface, in solid, liquid or gaseous materials, where their presence is not expected and not desired, as well as processes that contribute to the presence of a radioactive substance in the specified places;
f) mobile laboratory - a specialized vehicle in which mobile laboratory equipment and instruments are located, which are necessary for sampling, identification of radionuclides and determination of radiological characteristics;
g) volumetric activity - activity of radionuclides in a sample per unit volume: in gas - Bq/m3, in liquid - Bq/l;
h) sample - material to be examined that is prepared for laboratory examination;
i) internal exposure - exposure to ionizing radiation received as a result of a radionuclide entering the body.
2. Other terms used in this Rule have the same meaning as in the legislation in force in the field of radiation protection, nuclear safety and security.
Article 4. General requirements for sample collection during a nuclear or radiological emergency situation🔗
1. Measurement of gamma radiation of the environmental radiation background and sample collection shall be carried out in accordance with a pre-prepared plan, which shall specify the type of sample, date, time and place of collection, Global Positioning System (GPS) data, code and other additional information.
2. A sample taken during a nuclear or radiological emergency situation shall have the characteristics of the source or environment from which it was taken.
3. Personnel collecting samples shall carry the following equipment and tools:
a) Gamma radiation dosimeter (with a range of at least 0.1–100 µSv/h) with spare batteries;
b) Navigation device or topographic map (if software is not used);
c) Flashlight with spare batteries;
d) Protocols (material (paper) or electronic version):
d.a) Protocol of measurement of the dose rate of gamma radiation of the environmental radiation background (Annex 1);
d.b) Sample collection protocol (Annex 2);
d.c) Air sample collection protocol (Annex 3);
e) Writing materials for making notes;
f) Container with a volume of 3–5 litres with decontamination solution or clean water, or disposable decontamination materials for decontamination of the equipment, instruments and tools used during sample collection, as well as paper napkins or disposable cloth pieces for drying them;
g) Container or box for transportation of equipment, instruments and tools;
h) Additional equipment and instruments required for performing the tasks of radiological survey.
4. Before sample collection, the equipment, instruments and tools, as well as wireless communication, shall be checked for their proper functioning.
Article 5. Ensuring radiation protection and control of irradiation time on contaminated territories🔗
To ensure radiation protection and to reduce irradiation time on contaminated territories:
a) sample collection personnel shall wear personal protective equipment, including:
a.a) protective clothing;
a.b) respiratory protective equipment;
a.c) gloves, goggles and other protective equipment;
b) sample collection personnel shall wear a direct-reading or non-direct-reading dosimeter in accordance with the following rule:
b.a) the direct-reading dosimeter shall be placed in a polyethylene bag resistant to radioactive dust and aerosols and attached to the outside of the protective clothing, with an audible signal switched on (to record the accumulated dose of external irradiation or the gamma radiation dose rate);
b.b) the non-direct-reading dosimeter shall be attached under the protective clothing;
c) equipment, instruments and tools (for example, a gamma radiation dosimeter, a navigation device and a flashlight) shall be packed in a polyethylene bag so as to be protected from radioactive dust and aerosols;
d) the duration of work in the contaminated zone shall be planned in such a way that:
d.a) the irradiation dose of an emergency worker does not exceed the limit values established by the applicable legislation;
d.b) if necessary, the reference levels for occupational exposure in an emergency exposure situation are applied;
e) in the contaminated zone, personnel shall not:
e.a) eat, drink, smoke or touch the face, mouth or eyes;
e.b) remove personal protective equipment;
f) after completion of work in the contaminated zone, personnel:
f.a) shall take off protective clothing and remove respiratory protective equipment in a specially designated place;
f.b) shall ensure that the used disposable personal protective equipment (clothing, masks, gloves and others) is placed in an airtight polyethylene bag and handed over to the person responsible for handling radioactive waste;
f.c) shall leave personal protective equipment suitable for reuse in the appropriately designated area for decontamination.
Article 6. Identification of the sampling site🔗
Before sampling, personnel shall:
a) determine the sampling site indicated in the plan, by coordinates or address;
b) record the GPS coordinates of the sampling site in the sampling report and/or the air sampling report. If possible, personnel shall take a photograph of the sampling site and attach it to the reports.
Article 7. Requirements for sample packaging🔗
To ensure proper handling of the sample, it is necessary:
a) to place the sample in an appropriate container, seal it in an airtight polyethylene bag and attach a label with the unique sample code;
b) the sample placed in the airtight polyethylene bag shall be put into a container, which shall also be sealed to protect the label;
c) the sample code shall be recorded in the sampling report and/or the air sampling report.
Article 8. Decontamination of used equipment, instruments and tools🔗
1. After each sampling, decontamination of the used equipment, instruments or tools that were not protected from radioactive dust and aerosols shall be carried out by the following methods:
a) with decontamination solution or clean water;
b) with pieces of cloth intended for decontamination;
c) by drying with paper towels or disposable pieces of cloth.
2. Used pieces of cloth and towels shall be placed in an airtight polyethylene bag, on which an ionizing radiation warning sign shall be affixed, and shall be handed over to the person responsible for handling radioactive waste.
3. Collection of the liquid generated as a result of decontamination is not required when working in contaminated areas.
Article 9. Inspection of equipment, instruments and tools for contamination🔗
1. After sampling and decontamination of equipment, instruments and tools, personnel shall carry out dosimetric measurements to check for residual contamination.
2. If, after two decontamination attempts, the measured gamma radiation dose rate exceeds 0.3 µSv/h, or if the intensity of beta or alpha radiation exceeds the natural radiation background threefold, further use of the equipment, instruments and tools is prohibited.
Article 10. Transportation of the sample🔗
1. Transportation of the taken sample shall be carried out to the relevant laboratory for the purposes of further examination.
2. Samples shall be placed in a transport container or box in such a manner that their mixing or damage does not occur.
Article 11. Sampling of vegetables, fruit, berries and animal feed🔗
Sampling of vegetables, fruit, berries and animal feed shall be carried out in compliance with the following rule:
a) appropriate equipment and instruments shall be used (shovel, knife, scissors, airtight polyethylene bags, labels for identification of the sample) and a sampling protocol shall be completed;
b) green parts of plants shall be taken (not stems or roots, if they are not intended for human or animal food), as well as ripe vegetables, fruit or berries. If there is dew or frost on plants, vegetables, fruit or berries, sampling shall be carried out together with the dew and frost.
Article 12. Soil sampling🔗
1. When taking a soil sample, appropriate equipment and instruments shall be used (cylindrical soil sampler or other instrument, small shovel, hermetic polyethylene bags, labels for sample identification) and a sampling report shall be filled in.
2. Sampling shall not be carried out:
a) under trees or bushes;
b) in covered places;
c) near roads, ditches or slopes.
3. Before sampling, any grass shall be removed in the sampling zone.
4. Sampling shall be carried out from a depth of at least 5 cm. The sampling zone or the diameter of the instrument shall be recorded in the sampling report.
5. If snow fell after the passage of radioactive precipitation, the snow cover shall be removed from the soil before sampling. And in the case where snow fell before the radioactive precipitation reached the soil, first of all, a snow sample shall be taken, and then a soil sample shall be taken from the same place.
Article 13. Sediment sampling🔗
1. When taking a sediment sample, appropriate equipment and instruments shall be used (boat, depth measuring instrument, instruments necessary for taking a sample from the bottom, bucket and shovel for taking a sample of coastal sediment, hermetic polyethylene bags, labels for sample identification) and a sampling report shall be filled in.
2. Taking a sediment sample from a river shall be carried out from a part of the river with a calm current.
3. The depth shall be measured at the place from which the sample was taken.
4. Sampling shall be carried out with instruments intended for taking a sediment sample.
5. If such an instrument is not available, a bucket or shovel shall be used for taking a bottom sediment sample on the shore. The sampling depth shall be recorded in the sampling report.
Article 14. Air sampling🔗
1. When taking an air sample, appropriate equipment and instruments shall be used (air pump, filter holder, filters, hermetic polyethylene bags, labels for sample identification) and a sampling report shall be filled in.
2. The surface of the filter through which the air will flow shall be marked.
3. The filter holder shall be fixed at a height of 1 metre from the ground surface using a stand, a vehicle or another structure.
4. When switching on the air pump, the following shall be recorded in the air sampling report:
a) the time of the start of air flow suction;
b) the air flow rate (volume) at the time of the start of suction.
5. The air pump shall be switched on for at least 10 minutes.
6. Before switching off the air pump, the following shall be recorded in the air sampling report:
a) the time of the completion of air flow suction;
b) the air flow rate (volume) at the completion of suction.
7. The filter shall be carefully removed and placed in a hermetic polyethylene bag.
Article 15. Sampling of milk🔗
1. When sampling milk, appropriate equipment and instruments shall be used (a handled vessel, a polyethylene container with a screw cap (recommended volume: 1 litre), cheesecloth for filtering milk, a funnel, airtight polyethylene bags, labels for identification of the sample) and a sampling protocol shall be completed.
2. To pour the milk sample taken with a scoop into the container, a funnel shall be used, in which folded cheesecloth for filtering milk shall be placed.
3. The volume of the sample shall be at least 1 litre.
Article 16. Sampling of water🔗
1. When sampling water, appropriate equipment and instruments shall be used (a handled vessel, a polyethylene container with a screw cap (recommended volume: 1 litre), cheesecloth for filtering water, a funnel, airtight polyethylene bags, labels for identification of the sample) and a sampling protocol shall be completed.
2. Before sampling, the container and the funnel shall be rinsed with the water to be sampled. The water used for this purpose shall be poured out.
3. Sampling shall be carried out with a scoop and, using a funnel, poured into a polyethylene container.
4. The volume of the sample shall be at least 1 litre.
5. If necessary, the water shall be filtered through several layers of folded cloth placed in the funnel.
6. When sampling from open water bodies, sampling from excessively turbulent places or from turbid water shall be avoided. There shall be no sediment in the sample. Sampling shall not be carried out from puddles.
Article 17. Grass Sampling🔗
1. When sampling grass, appropriate equipment and instruments shall be used (a cylindrical soil sampler or another instrument, scissors or a knife, hermetic polyethylene bags, labels for sample identification) and a sampling report shall be completed.
2. Grass shall be cut using scissors or a sharp knife, at a height of 2 cm from the soil surface, in order to prevent contamination of the sample with soil.
3. For laboratory testing, only the green parts of plants shall be sampled.
Annex No. 1
Report on Measurement of the Gamma Radiation Dose Rate of the Environmental Radiation Background
N
__________________________________________________________________________
__________________________________________________________________________
Name and address of the legal entity performing the measurement
______________________________
Recipient of the report
_______________
Date
Date of measurement _______________
Instrument(s) used for the measurement _______________
Location
Latitude coordinates
Longitude coordinates
Time, hour, minute
Dose rate (mSv/h or µSv/h)
At a height of 1 m from the ground surface
Person performing the measurement
_____________________________
Position
___________________
Signature
___________________
Name and surname
Notes:
______________________________________________________________________________
______________________________________________________________________________.
Author of the notes:
________________________________
Position
____________________
Signature
____________________
Name and surname
Annex No. 2
Sampling report
N
__________________________________________________________________________
__________________________________________________________________________
Name and address of the legal entity performing the sampling
______________________________
Recipient of the report
__________________
Date
Type of sample
Date of sampling
Time of sampling
Place of sampling (address, description of the place)
GPS data: longitude, latitude of the sampling site
Sample code
Sample name, type
Additional information
Vegetables, fruit, berries and food
(name of the vegetable, fruit, berry, food)
Soil
Meadow;
Forest;
Arable land;
Other soil
1. Area of the cylindrical soil sampler or other instrument, cm², or diameter, cm _________________.
2. Sampling depth, cm _________________.
Sediment
River;
Lake;
Other
3. Sampling depth ______________________.
4. Name of the water reservoir ___________________
Milk
Cow's milk;
Goat's milk;
Other ____________
1. Date of the milk _______________, time ______.
2. Type of feed:
Grass
Hay
Other ______________________.
3. Pasture location ___________________________.
(description of the place)
4. GPS data:
Longitude________________, latitude________________
Water
Well water;
Open reservoir;
River;
Lake;
Other_________
Name of the water reservoir __________________________
Water supply water
Grass
Pasture grass;
Meadow grass.
Area of the cylindrical sampler or other instrument, cm² or diameter, cm _________________.
Notes:
__________________________________________________________
Sample collector
___________________________________
Position
____________________
Signature
____________________
Name and surname
Annex No. 3
Record of air sampling
N
__________________________________________________________________________
__________________________________________________________________________
Name and address of the legal entity performing the air sampling
______________________________
Recipient of the record
__________________
Date
Date of sampling _____________________
Time of sampling______________________
Place of sampling
______________________________________________________________
Description of the place
GPS data:
Longitude of the sampling place _____________, latitude______________
Filter type _____________________________________________________________________
Time of commencement of air flow suction ____________________________________________
Air suction rate (degree) at the commencement of suction________________________ l/min.
Time of completion of air flow suction _________________________________________
Air suction rate (degree) at the completion of suction___________________ l/min.
Sample code ______________________.
Notes:
______________________________________________________________________________
______________________________________________________________________________.
Sample collector
_______________________________
Position
____________________
Signature
____________________
Name and surname